Pistol Fogger
RIGEL RI8031
The best choice for air flow testing
- High density fog generation
- Lithium battery with status button
- Has a great variety of accessories, for every needs
Contact us to learn more about the RIGEL 8031 Pistol Fogger
Pistol Fogger
RIGEL RI8031
According to the relevant standard ISO 14644-3 ANNEX B7 the operators of cleanrooms are obliged to give periodically evidence of the actual air flow situation by a state of the art air flow mapper.
That’s why you had to choose a proper instrument for mapping your air flow.
The RI8031 is portable instrument and has a big autonomy based on battery package and 60 mL syringe, that gives you the opportunity to work up to 60 minutes continuously at its fullest.
The smoke density makes this instrument the best on the market and its wide range of accessories makes the RI8031 the most versatile instrument on his sector
Pistol Fogger
RIGEL RI8031
Technical specifications
- High density fog generation
- Lithium battery with status button
- Has a great variety of accessories, for every needs
Type of device | Handheld fog generator (pistol) |
Field of use | Visualize and test air streams in clean rooms and controlled contamination spaces (ISO 14644-3 – Section B.7 “Airflow direction test and visualization “) |
Fluid type (*) | Mixture of deionized water and glycol, sterilized with Gamma rays |
Fog characteristics | High density, persistent, white colour fog |
Tank capacity | Max. 60 mL (Syringe) |
Operating state and diagnostic test | Visible by means of blinking led with different operating modes |
Heater power | 30 W |
Evaporator temperature | Controlled and adjusted by microprocessor |
Activation command | Push button on the handle of the pistol |
Mixture consumption | About 0.6 mL/min |
Continuous fog generation time | About 60 min (starting with a fully charged battery) |
Electrical supply | Lithium-ion battery type RRC SMBUS 15 V 3200 mAh Rechargeable |
Battery charger | Type RRC-SMB-MBC 115-230 V 50-60 Hz 65 W |
Operating environmental requirements | Temperature from 0 °C to + 40 °C
Relative humidity 10 ÷ 90%
|
Storage environmental requirements | Instrument: Temperature from – 20 °C to + 60 °C Relative humidity 10 ÷ 90% not condensing Battery: Temperature from – 20 °C to + 20 °C Relative humidity 10 ÷ 70% not condensing |
Instrument casing | Anodized aluminum |
Dimensions (L x H x W) | 275 x 227 x 93 mm (including filter cartridge) |
Weight | About 1500 g (with battery and filter cartridge, no fluid) |